| |
| FAQ.... |
| |
| FAQ's on Security Motion Sensors |
|
|
| |
Question : Would this product be effective enough to avoid detection due to movement of pets? (such as cats, Dogs etc) |
| Answer : Yes, our model TrueSense PR723P has built-in pet-lense. It avoids false triggering due to motion of pets. |
| |
| FAQ's on
ecoLuz- Sensor Light Switch |
|
|
| |
Question : Once the light is switched ON for how much time it will remain ON? |
Answer : As long as motion is being detected ecoLuz shall keep the lights ON. Once the motion stops it will wait for SET time-out period. Time-out period could be set from 23 seconds to 4 minutes. Request for higher or lower Time-out period can also be served for minimum quantity of 100 nos. |
| |
Question : Can this sensor be linked to anything other than a lamp? Something like an alarm? |
Answer : Yes. You can connect either beeper or sounder or fans etc. Output Switch can handle any load upto 5Amp.
|
| |
Question : What is the detection range? |
Answer : ecoLuz is nearly 5 times more sensitive than available Chinese products in the market. It supports radius of 5 mtrs.
|
| |
Question : Can sensitivity is SET as per the customer application? |
Answer : Yes. Sometimes application needs to switch ON the lights with the slightest motion. For e.g in cabins once the person enters and takes his seat, motion of the person is minimal. However ecoLuz should keep the lights ON as long as cabin is occupied. This feature is not supported by many competitors.
|
| |
Question : Could two units be wired in parallel so that if either is triggered, the lights would come ON? |
Answer : Yes. Two units can be connected in parallel.
|
| |
Question : Can it be used to switch ON and OFF a fluorescent light or Fan? |
Answer : Fluorescent lights & fans are inductive loads. ecoLuz should be used for inductive loads upto 2.5Amp. For e.g you can connect about 12 40Watts Tubelights & about 3 to 4 fans. |
| |
|
|
|
|
Question : Is it possible to set the light level control so that the device operates throughout the day i.e during daylight as well as at night time?
|
Answer : Lux level at which sensor should start the operation can be SET from full day light to near darkness.
|
| |
Question : Is it possible to set the light level control so that the device operates throughout the day i.e during daylight as well as at night time? |
Answer : Lux level at which sensor should start the operation can be SET from full day light to near darkness. |
| |
Question : How have you ensured the reliability & Quality of ecoLuz? |
Answer : We are using one of the world's best, finest quality sensor (made in Germany). The product is developed by our own R & D. Product is manufactured with utmost care by our production department & is tested rigorously before packing. Many Chinese versions use poor quality of sensors which results into poor sensitivity and unreliability. Output stage of our circuit is very reliable with almost no failure. |
| |
Question : Is the life fluorescent lamp reduced by frequent switching? |
Answer : We recommends using electronic ballast for tubelights. This will not affect life due to frequent switching. With standard choke life may be reduced slightly as life mainly depends upon number of hours of operation.
|
| |
Question : Is ecoLuz available in Wall-Mount Model? |
Answer : Yes. We can make it available for MOQ of 100 nos.
|
| |
Question : Can you disable the Occupancy Sensor & switch ON lights permanently? |
Answer : Yes. Using over-riding mode you can switch ON the lights permanently.
|
| |
Question : Comparison between ecoLuz & other Chinese products? |
Answer :
ecoLuz |
Other Chinese Products |
| Range is 5 ` 8m radius |
Range is 1 ` 2m radius |
| Operating Voltage 180`260v suitable for Indian conditions |
Low supply voltage range |
| Long relay life due to high quality relay and switching at zero crossing |
Random switching hence low life |
| 1 year manufacturer warranty |
No manufacturer warranty |
|
| |
|
|
 |
| FAQ's on GAS Leak Detector |
|
| |
Question : Is this detector stand alone type? |
Answer : TS230LHB is Standalone Type. TS12LHR can be integrated with Home Automation & Security System provided that these systems have NO & NC contacts. |
| |
Question : Is there any reset switch with this detector? |
Answer : Detector is Auto-Resettable. |
| |
Question : What is the detection range of Gas Leak Detector? |
Answer : The performance of Gas Leak Detector is not measured in terms of range. When gas leaks & the gas particles reach the sensor & when concentration reaches 10% of LEL, warning is given. Hence we recommend to position or place this device as close as possible to the gas source. |
| |
Question : Does this Gas Leak Detector have battery backup or battery operated models? |
Answer : Fully battery operated Gas Leak Detectors are not available anywhere in the world. Reason being the current consumed by such device/ detector/ sensor would drain the standard battery within 6-7 days. Hence it's not practical to keep replacing the batteries after every 7 days. We do not supply battery operated gas leak detector. However we do have model with rechargeable battery backup. In case of power failure this detector with rechargeable battery will switch to battery mode.
|
| |
Question : Isn't it dangerous to have an electrical socket near the gas source? |
Answer : It is not dangerous to have an electrical socket near the gas source. In any typical kitchen there are several electrical home appliances which operate on electricity when connected to the electrical socket like Mixer, Grinder, Fridge, Oven etc. In case of leakage of gas & gas concentration reaching LEL then somebody might switch the power ON/Off, the spark which happens at the switch contact might cause fire. O ur detector gives warning much ahead of dangerous level. Also no switching happens inside the circuit as the circuit is solid state. Hence it's not dangerous to have an electrical socket near the gas source. |
| |
Question : What is the life of Gas Leak Detector? |
Answer : Life of the sensor inside Gas Leak Detector is 2 years. We recommend replacing the gas leak detector after 2 years of use. |
| |
Question : Comparison between TrueSafe & other Chinese products? |
Answer :
TrueSafe LPG Gas Leak Detector |
Other Chinese Products |
| Microprocessor based product |
Ordinary logic switching |
| Intelligence avoids false calls |
Prone to false calls as non-intelligence |
| Temperature compensation |
No temperature compensation results into false calls at high temperature |
| Heat Detection feature |
No heat detection feature |
| Kitchen Platform Panel mounting increases its effectiveness by factor of 2 |
Wall mounting is useful only near cylinder |
| Wide options available including Bargraph display & flasher |
Limited options |
| Sensor replacement is possible |
Manufacturer not accessible hence repair & support is near impossible |
| 1 year manufacturer warranty |
No manufacturer warranty |
|
| |
|
|
|
| FAQ's on Alcohol Breath Analyser |
|
| |
Question : What is life of sensor? |
Answer : Life of sensor is about 2 years. However it depends upon the usage. Heavy usage may result in to the lesser sensor life. |
| |
Question : Do the mouth piece/ pipe need to be changed each time? |
Answer : Yes, due to health concern (hygiene), the mouth piece/ pipe need to be changed for every single operation. |
| |
Question : What is the cost of mouth piece/ pipe? |
Answer : Typically it would cost Rs 2 for Citizen Model & Rs 5 for Police Model. |
| |
Question : What is the type of sensor? |
Answer : In Citizen Model the sensor used is semiconductor sensor. In Police Model the sensor used is Fuel/ Electro-chemical sensor. |
| |
Question : How much is the device Warm-up time? |
Answer : Typically 30-45 seconds warm up time. |
| |
Question : How much is the device Warm-up time? |
Answer : Typically 30-45 seconds warm up time. |
| |
Question : What is the blowing time? |
Answer : 5 seconds |
| |
Question : What is cost of sensor replacement? |
Answer : The cost for sensor for citizen model is Rs. 2500/-. The cost for sensor for Police model is Rs. 4500/- |
| |
Question : What is the difference between Citizen & Police Model? |
Answer :
Cityzen Model |
Police Model |
| Printing Facility - Not Available |
Printing Facility - Printer Available |
| Sensor- Semiconductor Sensor |
Sensor- Fuel/ Electro-chemical Sensor |
| Application For Personal Usage |
Application for Police, commercial, security purpose |
| Sensor Replacement cost = Rs. 2500 |
Sensor Replacement cost = Rs. 4500 |
| Weight = 64 g Battery excluded |
Weight |
| Dimensions 103×65×27mm (L×W×H) |
Dimensions |
| Non ruggedized Construction |
Ruggedized Construction |
|
| |
|
|
|
| |